MONITOR-H61
Remote Management Automation for Electrical Substations

  • Wi-Fi b/g/n
  • Supports UDP and TCP
  • 5G/4G/3G/2G: Global mobile network, in the USA, Europe, and Asia
  • TFT color touchscreen display (optional)
  • Monitor-DIO: 24 digital inputs/8 relay outputs
  • Monitor-AI: 24 analog inputs
  • Temperature (PT100 or PT1000)
  • 8 analog inputs (0/4..20mA or 0-10V)

Description

Monitor-H61 is both a remote terminal unit (RTU) and a data logger designed for remote monitoring of electrical substations, using digital and analog inputs/outputs (position or fault signaling contacts of equipment, DGPT2 signaling contacts, PT100 or PT1000 temperature sensors, etc.), and RS485 and Ethernet ports to integrate all existing measurement or control devices, communicating via the Modbus protocol (digital meters, electrical measurement units, digital protection relays, temperature and humidity sensors, etc.).

It is compatible with all meters, measurement units, and protection relays on the market (ABB, Elster, Schneider Electric, GE, etc.) communicating via Modbus. Monitor-H61 can manage up to 32 Modbus slave devices, including its own input/output expansion modules. It integrates easily and intuitively into any Modbus-compatible SCADA system on the market.

Functionality:

  • Simultaneous data transmission over 4G/3G/2G network, Wi-Fi, and Ethernet
  • Internal data recording memory of 8 MB
  • Extension slot for SD memory card (up to 32 GB)
  • Data and alarms via 4G, SMS, and Ethernet
  • SMS alarm to mobile phone
  • Remote control of relay outputs via SMS or through SCADA or smartphone application (Ethernet or 4G)
  • Parameter setting and downloading of recorded data via USB, serial connection, Ethernet, or 4G
  • Programmable data recording interval
  • Multi I/O channels: temperature, analog channels, digital channels, pulse or relay, RS485 Modbus
  • Digital alarm input and relay output
  • Up to 4 temperature sensors (PT100 or PT1000)
  • Modbus support via RS485 and Ethernet
  • Support for fixed IP addresses and DDNS
  • Analysis of recorded data via M-Visu software (free)

Technical specifications:

4G/3G/2G
  • Supports UDP and TCP on the mobile network

SMS
  • Send customized SMS alarms to up to 20 cell phones

  • User-programmable SMS text

Communication ports
  • RS485: Modbus-RTU protocol (Master/Slave)

  • Ethernet: Supports UDP and TCP / Supports Modbus TCP

Inputs / outputs
  • 8 digital inputs

  • 4 configurable temperature inputs (PT100 or PT1000)

  • 2 programmable analog inputs (0…20mA , 4…20mA or 0-10V)

  • 8 relay outputs

  • 1 transistor output (pulse or digital)

  • Several Extension Modules

Power supply
  • 12 to 36V DC

Product Documentations